I purchase ARLEC Premium Surge Protectors from Bunning in Dec 2025 for $18.67 each (I got an additional 5% trade discount.). I Tore apart a unit to see what it was made of. I was impressed with the construction and purchase a total of 6 units, including the tear down unit which I do not intent to bring back into service, plus a spare. This allows a unit to be installed in each bedroom and study, which also aligns with the household general outlet power circuits. This is to protect the main expensive electronics from surge failure.

Circuit Diagram and BoM

I created the following circuit schematic diagram and BoM (Bill of Materials)

Circuit Diagram

The thermal fuses were installed between their varistors, as can be seen in the photos, but is not clear in the schematic. Power for the status LEDs is taken downstream the main thermal switch for the active to neutral varsistors (RV1 and RV2). If there is power here the Surge protected LED will light. If the base of the Ground LED transistor Q1 is connected to a suitable earth connection the transistor will not be activated allowing the Ground LED to light. RV3 to RV6 combined with TVS1 provide addtional surge capacity and help protect against excessive ground fault conditions.

Bill of Materials

Item Qty Reference Comment
D1 1 Diode Small Power or Signal Type
D2, D3 2 LED Green 5mm rectangle
D4 1 Diode Small Signal Type, Glass
J1, J2 2 Fuse Small L5CT T5AH 250V, Pig Tailed
Q1 1 Darlinigton NPN MPS A13 313
R1 1 R100k 1/2W
R2, R3 2 R10M 1/4W
RV1, RV2, RV3, RV4, RV5, RV6 6 Varistor VDR 14D471K
SW1, SW2, SW3 3 Temperature Switch SPST NCSET Y2 5A 250V 115deg.C
TVS1 1 GDT Surging 600

Following comments on parts naming:

  • J1, J2 are called up as Jumpers on the circuit boards, however the install components look like 5A slow action fuses.
  • SW1, SW2, SW3 are called up as F1, F2 and F3 respectively on the circuit board.
  • The circuit board call up TSV1 as TSV (Transient Voltage Suppression Diode), however the installed device looks like a GDT (Gas Discharge Tube), on part text SURGING 600.

Photos

Photos showing unit front and back, as supplied

Photos showing the case split and internals. It is interesting to see the neutral wire copper to brass pin weld has failed. I did not test the unit before splitting and am confident that this connection was not stressed when split. Note the heat shrink enshrouding the varsistors and thermal fuses, I speculate the following related purposes: first to enclose the failure flame / and explosion of a varsistor and second to enclose the heat released from a failing varsistor(s) allowing faster action of the thermal fuse.

Photos of the thermal fuses:

Photos of the MOV and Transistor:

The product packaging specification photo.