{{tag> | {{tag> | ||
======NUT (Network UPS Tools) Setup====== | ======NUT (Network UPS Tools) Setup====== | ||
+ | I purchased my current main UPS the Powershield Commander RT PSCRT1100 / Voltronic Power Otima II 1.1K in 2014 and setup NUT about this time, including early conversion to systemd scripts. | ||
- | NUT is an open source network monitoring and control system. I use a Powershield Commander RT PSCRT1100 a 1100VA/ | + | By the way a couple years ago the UPS battery fail alarm went off. It would seem the UPS batteries failed after about 5-6 years of operation. |
+ | |||
+ | NUT is an open source network monitoring and control system. I use a Powershield Commander RT PSCRT1100 a 1100VA/ | ||
It turns out the '' | It turns out the '' | ||
Line 271: | Line 274: | ||
</ | </ | ||
- | Example to disable the UPS beeper: '' | + | Example to disable the UPS beeper: '' |
The command will prompt for a user then password. | The command will prompt for a user then password. | ||
+ | |||
< | < | ||
T | T |